XFT Series


Latest heavy-duty industrial hazard warning beacon.
Unique ratchet system allowing two or more units to be linked together and orientated in
respect to each other at 10 degree intervals.
Incorporates external fixing holes - 4 x 6.5mm dia. on 120 x 120mm pattern.
Alternate drillouts on 51mm centres and 3 drillouts on 100mm PCD.
Dual M20 entries - Blanking plug and cable gland supplied.
High grade engineering, UV-stabilised Polycarbonate Base and Lens.
| Cage Guard : |
n/a |
| Wall Mounting Bracket: |
MB7 |
11 Joule Xenon Strobe model
High energy xenon strobe beacon.
Repetitive Dual Flash (DH) and Single Flash (SH) models.
Long-life xenon tube - typically > 20,000,000 flashes.
12Vuc, 24Vuc, 115Vac and 230Vac models.
/SYNC option available to allow multiple units to be flashed in synchronism.
360° All-round and 270° All-over visibility.
Special 240Vdc model also available.
Lens Colours:    
| Supply voltage |
12v uc |
24v uc |
115v ac |
230v ac |
| Supply voltage limits |
15% |
| Supply current |
1.36A |
680mA |
160mA |
80mA |
| Luminous Intensity |
Red |
44Cd |
| Amber |
132Cd |
| Green |
132Cd |
| Blue |
44Cd |
| Clear |
220Cd |
| Flash Energy |
11J |
| Flash/min SH |
60 fpm (1Hz) |
| Flash/min DH |
2 x 60 fpm (2Hz) |
Flash event rate
adjustment |
User selectable 30, 45, 60 & 90 fepm |
| Temperature limits |
-40C, +55C |
| IEC protection class |
IP65 |
Typical Order Code: XFT/AC/115/DH/11J/Red
5 Joule Multi-Voltage Xenon Strobe model
High energy xenon strobe beacon.
Single Flash (SH) model.
Long-life xenon tube - typically > 20,000,000 flashes.
12-100Vdc (12-72Vac) automatic voltage-ranging 5 Joule model (VRA).
/SYNC option available to allow multiple units to be flashed in synchronism.
360° All-round and 270° All-over visibility.
Lens Colours:    
| Supply voltage |
VRA (10 to 100v dc / 10 to 70v ac) |
| Supply current |
630mA @ 12v to 70mA @ 100v |
| Luminous Intensity |
Red |
20Cd |
| Amber |
60Cd |
| Green |
60Cd |
| Blue |
20Cd |
| Clear |
100Cd |
| Flash Energy |
5J |
| Flash/min SH |
60 fpm (1Hz) |
| Flash/min DH |
n/a |
Flash event rate
adjustment |
User selectable 30, 45, 60 & 90 fepm |
| Temperature limits |
-40C, +55C |
| IEC protection class |
IP65 |
Typical Order Code: XFT/UC/VRA/SH/5J/Red
|
|
|